Carbonatite-derived, carbonate-bearing fluorapatite compositions from Kovdor, Sokli, Bukusu, Catalao II, and Glenover (NERC Grant NE/R013403/1)
Mineralogical data relating to carbonate-bearing fluorapatite from the Bukusu, Catalao II, Sokli, Kovdor and Glenover carboantite complexes. Report on the data is here: Broom-Fendley, S., Siegfried, P.R., Wall, F. et al. The origin and composition of carbonatite-derived carbonate-bearing fluorapatite deposits. Miner Deposita 56, 863-884 (2021). https://doi.org/10.1007/s00126-020-01010-7.
Simple
- Date (Creation)
- 2023-10-03
- Citation identifier
- http://data.bgs.ac.uk/id/dataHolding/13608137
- Point of contact
-
Organisation name Individual name Electronic mail address Role University of Exeter
Sam Broom-Fendley
not available
Originator British Geological Survey
Enquiries
not available
Distributor British Geological Survey
Enquiries
not available
Point of contact
- Maintenance and update frequency
- notApplicable
-
GEMET - INSPIRE themes, version 1.0
-
BGS Thesaurus of Geosciences
-
-
NGDC Deposited Data
-
Apatite
-
Carbonatite
-
- dataCentre
- Keywords
-
-
NERC_DDC
-
- Access constraints
- Other restrictions
- Other constraints
- licenceOGL
- Use constraints
- Other restrictions
- Other constraints
-
The copyright of materials derived from the British Geological Survey's work is vested in the Natural Environment Research Council [NERC]. No part of this work may be reproduced or transmitted in any form or by any means, or stored in a retrieval system of any nature, without the prior permission of the copyright holder, via the BGS Intellectual Property Rights Manager. Use by customers of information provided by the BGS, is at the customer's own risk. In view of the disparate sources of information at BGS's disposal, including such material donated to BGS, that BGS accepts in good faith as being accurate, the Natural Environment Research Council (NERC) gives no warranty, expressed or implied, as to the quality or accuracy of the information supplied, or to the information's suitability for any use. NERC/BGS accepts no liability whatever in respect of loss, damage, injury or other occurence however caused.
- Other constraints
-
Available under the Open Government Licence subject to the following acknowledgement accompanying the reproduced NERC materials "Contains NERC materials ©NERC [year]"
- Language
- English
- Topic category
-
- Geoscientific information
- Begin date
- 2018-10-01
- End date
- 2020-10-01
Reference System Information
- Distribution format
-
Name Version MS Excel
- Distributor contact
-
Organisation name Individual name Electronic mail address Role British Geological Survey
Enquiries
not available
Distributor
- OnLine resource
-
Protocol Linkage Name https://webapps.bgs.ac.uk/services/ngdc/accessions/index.html#item182510 Data
- Hierarchy level
- Non geographic dataset
- Other
-
non geographic dataset
Conformance result
- Title
-
INSPIRE Implementing rules laying down technical arrangements for the interoperability and harmonisation of Geology
- Date (Publication)
- 2011
- Explanation
-
See the referenced specification
- Pass
- No
Conformance result
- Title
-
Commission Regulation (EU) No 1089/2010 of 23 November 2010 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards interoperability of spatial data sets and services
- Date (Publication)
- 2010-12-08
- Explanation
-
See http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2010:323:0011:0102:EN:PDF
- Pass
- No
- Statement
-
Details of the methodology are present here: https://doi.org/10.1007/s00126-020-01010-7. In summary: Electron probe micro analyses (EPMA) were undertaken using a JEOL JXA 8200 instrument, operated with a 10 nA, 15 kV beam defocussed to a 5-?m spot. Trace elements were analysed using LA-ICP-MS, with a 100 ?m spot, coupled to an Agilent 7500c ICP-MS operating in reaction mode, with a flow rate of 2.5 ml min?1 H2. Ablation at Camborne School of Mines utilised a New Wave Research 213 nm laser coupled to an Agilent 7700 ICP-MS. Median Ca concentrations were used as the internal standard composition and NIST SRM 610 was used for calibration. Infrared spectra were collected for polished surfaces using a ThermoNicolet i10 FTIR spectrometer fitted with a Ge-tipped attenuated total reflectance head, housed at the University of Bristol. Keywords: Apatite, carbonatite Begin date: 01/10/2018 End date: 01/10/2020 Geographical extent: Samples BM1993, P7 15-17 are from the Loiso area, Sokli, Finland. Exact location unknown. Samples SoS_10-12 are from the apatite-francolite quarry, ~500 m south of the Zheleznyi Fe mine, Kovdor, Russia. Exact location unknown. MR32594 is from the southern area of the Bukusu carbonatite, west of Busumbu, Uganda. Exact location unknown. HTAC_100 is from the mine dumps at Glenover, South Africa. Exact location unknown. BRR1 is from the Catalao II phosphate pit, Brazil Exact location unknown.
Metadata
- File identifier
- 0b5eea83-19d9-5017-e063-0937940ad151 XML
- Metadata language
- English
- Hierarchy level
- Non geographic dataset
- Hierarchy level name
-
non geographic dataset
- Date stamp
- 2024-12-07
- Metadata standard name
- UK GEMINI
- Metadata standard version
-
2.3
- Metadata author
-
Organisation name Individual name Electronic mail address Role British Geological Survey
Point of contact
- Dataset URI